Skip to content

Keg-1. Version 1

Three nodes, one panel, one keg.

The power plant sits outside: panel, MPPT controller, battery, main fuse. One fused 12 V feed enters through a cable gland to a five-slot fuse block. A fault on one node opens one fuse and leaves the other two running. That is the keg-scale version of redundant power distribution in a data hall.

Keg-1 cross-sectionA five-gallon stainless keg in section. Three Raspberry Pi 5 nodes on the left wall conduct heat through a 3 mm aluminum plate to the keg shell. A fuse block, three buck converters, and a gigabit switch sit on the right. Sealed penetrations are on the upper sidewall. Four temperature probes, a humidity sensor, and desiccant are marked.DS18B20, airDS18B20, SoCDS18B20, outsideDS18B20, wallPi 5 ×33 mm Al plateIP68 gland, 12 V inRJ45 bulkhead, data outGbE switch3× buck 5.1 VFuse block B1–B5silica gelBME280pressure-relief valve, never disabled5 gal 304 stainless ball-lock keg, ≈ 8.5 in × 25 in
Phase
0Pre-build
Measurements
0logged
Claims under test
10graded
Budget
$1,000$0 spent
As of
2026-10-26

Power path.

100 W monocrystalline panel, doubling as the sunshade, into an MPPT controller with a LiFePO₄ profile, into a 12.8 V nominal, 20 Ah battery with integrated BMS. The main fuse sits within 7 inches of the positive post, per marine wiring convention. Inside the keg, slots B1 to B3 feed three 12 V to 5.1 V buck converters, one per node; B4 feeds the switch; B5 feeds the 3.3 V sensor rail and is the spare.

Load at the 12 V busIdle WFull WGrade
Raspberry Pi 5, per node, ×33.07.0PLAUSIBLE
5-port gigabit switch2.02.0PLAUSIBLE
Sensor rail and MPPT self-use0.50.5PLAUSIBLE
Buck conversion efficiency0.90PLAUSIBLE
Cluster total at bus12.826.1derived

Pi figures are typical values reported for the platform, not measurements. INA226 #2 replaces them at idle and under one through four jobs.

Sixteen weeks, four gates.

  1. 01Weeks 1–4

    Energy

    Vol. I, Poles. $315

    Panel, MPPT controller, LiFePO₄ battery, the main fuse, the fused 12 V bus, and the first node as sensor host.

    Gate. Node 1 runs from the fused bus; both INA226 monitors report sensible watts in and watts out.

  2. 02Weeks 5–8

    Compute

    Vol. II, Chips. $185

    Nodes 2 and 3, the gigabit switch, wired network, and a three-node load test under a stop rule set in advance.

    Gate. Three-node load test completes under the pre-set stop rule without a brownout.

  3. 03Weeks 9–12

    Keg

    Vol. III, Halls. $265

    Primer and safety-orange paint, IP68 gland and RJ45 bulkhead, the passive heat path to the keg wall, sensors, desiccant.

    Gate. Water-only leak test of the empty keg, then a seven-day sealed soak with a flat humidity trend.

  4. 04Weeks 13–16

    Deploy

    Vol. IV, Deployed. $65

    Land, tethered water, and a ground-based orbit analog: simulated eclipse power cycles and radiation-only cooling.

    Gate. Eclipse cycles logged; radiation-only cooling run completes with SoC below throttle.

Bill of materials, estimate against actual.

Prepared September 30, 2026. Only two lines were checked against live listings: the Pi 5 boards and the keg. The rest are estimates. Actual prices are written beside each estimate at purchase, and the gap is the project’s first cost-variance dataset. Assumed on hand: a laptop, a drill, hand tools.

ItemQtyEstimatePrice statusActualVariance
01Energy$315
Digital multimeter1$25Estimate——
LiFePO₄ battery, 12 V 20 Ah, BMS1$80Estimate——
Solar panel, 100 W 12 V mono1$80Estimate——
MPPT charge controller, 10–20 A1$40Estimate——
Buck converters, 12 V to 5.1 V 5 A4$25Estimate——
Fuses, holders, Powerpole, wire1$35Estimate——
Sensors: 2× INA226, 4× DS18B20, BME2801$30Estimate——
02Compute$185
Raspberry Pi 5, 1 GB3$135Checked 9/2026——
microSD, 32 GB high endurance3$30Estimate——
5-port gigabit switch1$20Estimate——
03Keg$265
5-gallon ball-lock keg, 304 stainless, new1$130Checked 9/2026——
Self-etching primer, safety-orange enamel1$30Estimate——
Heat path: heatsinks, 3 mm Al plate, pads1$35Estimate——
IP68 gland, RJ45 bulkhead, sealant, step bit1$30Estimate——
Outdoor Cat6 and patch cables1$30Estimate——
Desiccant and humidity cards1$10Estimate——
04Deploy$65
Water tether kit1$25Estimate——
Panel stand / canopy1$40Estimate——
Parts subtotal$830——
Contingency, 20.5%: price swings, shipping, tax, mistakes$170——
Project budget$1,000——

Energy and the enclosure are 70% of parts cost. Compute is under a fifth. That is the keg-scale version of the warehouse observation that power and cooling, not servers, set the capital shape.

Ten claims under test.

Each design claim is paired with the instrument that will test it and the expectation it must beat or replace. Where a value is withheld as a lesson, the builder produces the number before buying the part. Results land in the build log and replace these rows one at a time.

ClaimGradeInstrumentTestPre-build expectationMeasured
Panel open-circuit voltage matches its labelPLAUSIBLEMultimeter, DC VFull sun, then half-shadedNear label Vₒₑ; shading moves voltage little, current a lotnot yet
Main fuse is sized to the wireLESSONMultimeter, continuityContinuity across installed fuse; fused-lead V equals battery VRating per I_wire ≥ I_fuse ≥ 1.25 × I_cont,max; value recorded in lognot yet
Buck holds 5.1 V under loadPLAUSIBLEUSB-C inline meterOutput before any Pi, then under load≥ 5.0 V at 3 A; no Pi under-voltage flagnot yet
Per-node idle and full-load wattsPLAUSIBLEINA226 #2Idle, then 1–4 jobs on one node2.5–3.5 W idle; 6–8 W full; second job costs less than the firstnot yet
Three-node full load at the busPLAUSIBLEINA226 #2Three-node stress under stop ruleAbout 26 W, ±20%not yet
Night idle fits usable battery energyPLAUSIBLEINA226 #2, MPPT SoCOne overnight log, sunset to sunrise≥ 26 Wh above the 51 Wh reserve at dawn in winter; more in summernot yet
INA226 range covers bus currentLESSONINA226 #2 vs multimeterCompare at 1–5 AAgreement within shunt tolerance; range per 81.92 mV / R_shuntnot yet
Shell rise is small; the SoC-to-plate interface dominatesSPECULATIVE4× DS18B20Three-node load, 60 min, sealedShell 5–10 K above ambient; SoC under 80 °Cnot yet
Keg stays dry when sealedPLAUSIBLEBME280Seven-day sealed soak, then tethered waterFlat humidity trend; any rise is a leaknot yet
Daily harvest scales with peak sun hoursPLAUSIBLEINA226 #1Seven clear and seven cloudy daysAbout 70 Wh per PSH; derate 0.6–0.8not yet

Rules that gate every step.

Two further constraints follow from the hardware. Pi GPIO pins operate at 3.3 V and are not 5 V tolerant, so the sensor rail is 3.3 V only. Every load test stays above the BMS low-voltage cutoff; a node that browns out has already reset, and there is no recovery step to prove.